To prevent the differential protection scheme from picking up under such conditions, a percentage differential protection scheme is used. Differential protection of transformer differential. A currentbased solution for transformer differential. Reactors and capacitors there are two basic types of differential protection. Testing differential protection 87 provides stepbystep procedures for testing the most common differential protection applications. Pdf optimizing differential protection settings for power. Differential protection principle differential overcurrent protection. In addition, interposing cts may be used to reduce the effective lead burden of long secondary leads. Pdf a currentbased solution for transformer differential. Explain challenges of transformer differential protection understand need for tap, phase, and zerosequence compensation and how they work understand how transformer differential relays are made secure for inrush and overexcitation transformer differential protection presentation objectives. Differential protection is a unittype protection for a specified zone or piece of equipment. Percentage restrained differential protection is one of the oldest. Power transformer differential protection using current and.
Alexander ge corporate ge power management research and development malvern, pa schenectady, ny updated and presented by subhash c. The highimpedance input is created by an internal impedance, typically resistive, of 2000 ohms or higher. Strictly speaking the rc tells us how much current a relay will use to restrain based on the currents. Differential relays are very sensitive to the faults occurred within the zone of protection but they are least sensitive to the faults that occur outside the protected zone. Percentage differential relays type lid introduction type ijd52a ltd 52 b ird53c ijd53d elements 3 1 3 the type isd relays comprise a group that is used for differential protection of alternating cur rent equipment.
Aug 30, 2018 any internal fault inside the stator winding is cleared by mainly differential protection scheme of the generator or alternator. Principles of differential relaying my protection guide. Multipurpose percentage radsc restraint differential. Differential protection of generator or alternator electrical4u. To determine the correct tap setting, calculate the currents delivered to the relay at full load on the trans. Therefore, differential protection of transformer should be provided with a proportional bias of an amount which exceeds in effect the maximum ratio deviation. Thompson, schweitzer engineering laboratories, inc. The differential zone of the relay can include up to. Jan 14, 2017 a differential relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount. Comparing current flowing into a line to the current flowing out of the same line allows for a simple protection scheme. Sel587 current differential relay schweitzer engineering. Through fault means a fault outside the zone of protection. Differential protection is applicable to all parts of the power system. Differential protection summary overcurrent differential scheme is simple and economical but does not respond well to unequal ct performance percentage differential scheme responds better to ct saturation differential principle provides best protection selectivity and speed.
Generator stator protection, underover voltage, under. With the differential protection relaying, the cts at both end of the stator windings must be same. Biaseddifferential protection theory and application eep. Line differential protection modeling with co mposite current and volt age hamzah eteruddin 61 the relay commanded the breaker to trip at an equal period of time i. Percentage differential type ijd relays introduction inter. This system gives protection against phase to phase faults and phase to ground faults to the power transformers. Type ca percentage differential relay for generator. Relay security is achieved by an optimized set of userselectable restraining and blocking elements. Within the limits of the accuracy of the cts and the relays, true bus differential relaying will detect all faults on the protected bus. Control facilitate traditional or advanced protection schemes using selogic. Differential protection electrical impedance relay. Type ca percentage differential relay for generator protection 50 and 60 hertz instruction.
The sel587 current differential relay combines overcurrent and differential elements in an easytoapply power apparatus differential protection package. The principles of differential protection you must. Biased differential protection theory and application on. Transformer protection principles ge grid solutions. Current differential line protection current differential relaying is a method of extending the benefits of differential protection as applied to transformers, buses or generators to the protection of transmission lines. Percentage differential protection for transformers the percentage differential protection or merzprice protection based on the circulating current principle can also be used for the transformers. Quite a number of protection systems have been designed for busbars. The percentage differential relay is defined as the relay that operates on the phase difference of two or more similar electrical quantities exceeds a predetermined amount. Percentage differential protection slope in differential.
For the protection of ac rotating machinery and power transformers. The percentage differential principle originally developed for transformer and generator protection was extended for use on short transmission lines already in the 1930s, and is still widely in use. The ca26 relay provides differential protection for both 2 and 3winding transformers. Unit ct value a t60 percent differential element per unit value refers to setting scaled to the identified unit ct. Pdf this paper presents an improved methodology to optimize the differential relay settings. Patel ge power management malvern, pa presented at the electric council of new england. In modern numerical differential protection relay two. Due to the long lead time for repair of and replacement of transformers, a major goal of transformer protection is limiting the damage to a faulted transformer. This popular scheme is known as biased differential protection or merzprice protection. Protection use single or dualslope percentagerestraint differential characteristics and overcurrent elements. Transformer differential protection scheme with internal faults detection algorithm using second harmonics restrain and fifth harmonics blocking logic. Set the differential elements with either a single or dualslope percentage differential characteristic, as shown below.
Differential protection free download as powerpoint presentation. Generally instantaneous attracted armature type relays are used for this purpose because all they have high speed operation. Backup overcurrent protection provides highspeed operation, even with severe ct saturation, using the sel adaptive overcurrent element. Apr 28, 2018 as discussed in the post transformer differential protection, differential protection is supposed to operate for the internal faults or for the zone of protection it is intended for. Sep 08, 2016 general scheme of differential protection 6. In percentage differential protection, we provide a slope feature to the differential protection relay. The slope characteristic provides high sensitivity when low levels of current. Although nowadays differential protection is achieved numerically, in order to understand the principles of differential protection it is useful to analyze the ubiquitous electromechanical relay. The differential protection of transformer has many advantages over other schemes of protection. Transformer differential protection percentage restraint differential protective relays have. It is the advanced form of differential protection relay. Differential protection of transformer differential relays.
Explain challenges of transformer differential protection understand need for tap, phase, and zerosequence compensation and how they work understand how transformer differential relays are made secure for inrush and overexcitation. Directional blocking protection of these, 1 is suitable for small substations only, while 4 and 5 have become obsolete. A new approach to current differential protection for transmission lines m. Among them differential relay is very commonly used relay for protecting transformers and generators from localised faults. Differential protection is supposed to operate for the internal faults or for the zone of protection it is intended for. What are the advantages of percentage differential relay. It is a static device, totally enclosed and usually oil immersed, and. A sensitive current element in series with the highimpedance element is calibrated in volts based on the voltage drop across the internal impedance. A new approach to current differential protection for. The only difference between them is the restraining coil. Abstractpercentage restrained differential protection is one. The percentage differential relay is defined as the relay that operates on the phase difference of two or more similar electrical quantities exceeds a. T60 percent differential calculations 2 ge power management it is important for the user to understand the slope 1 and 2 percentage settings and the minimum pickup, break 1, and break 2 perunit values.
Percentage differential protection is the most widely used scheme for the protection of transformers rated 10 mva and above. Percentage restrained differential relays measure the. When the relay is correctly set, one screw must be in the lower row of holes at the correct tap value and the other must be in the hole directly above. Percentage differential protection slope transformer. Slope calculation for transformer differential protection. It is based on the fact that it is only in the case of faults internal to the zone that the differential current difference between input and output currents will be high however, the differential current can sometimes be substantial even without an internal fault. The faults occur in the transformer inside the insulating oil can be detected by buchholz relay. Differential protection of a transformer the transformer is one of the major equipment in power system. This course explains protection relay selection process by detailing how to protect against each fault type or abnormal condition. Choose from common or independent harmonic blocking or restraint. The percentage restraint characteristic requires that the differential current be greater than a percentage of the through restraint current. May 15, 2018 generally differential protection is provided in the electrical power transformer rated more than 5mva. The term biased differential or percentage differential is based on the fact that the operating threshold increases with the through current.
About five seconds after operation the trip circuit is opened and the differential circuit shorted by an auxiliary latching relay rxmvb 2. Problem statement article pdf available in ieee transactions on power delivery 164. At maximum through fault current, the spill output produced by the small percentage unbalance may be substantial. It helps you to shape up your technical skills in your. Modelling and simulation of protection for power transformer. The differential protection is provided in the generator by using longitudinal differential relay. In this paper, differential protection using relay is presented. Current differential line protection setting consideration. Acces pdf ge bdd relay manual ge bdd relay manual when somebody should go to the ebook stores, search opening by shop. Multipurpose percentage restraint differential protection radsc 1mrk 509 016ben page 2 application contd interposing cts are used to balance the main ct ratios when necessary. In this type of protection the electrical quantities entering and leaving the protected zone or area are compared by current transformers c.
Understand the basic characteristics of differential protection. Type ca percentage differential relay for transformer protection. Protection relays differential relays b high impedance differential protection. Through fault means a fault outside the zone of protec. Mohammed tawfeeq alzuhairi 321 differential protection differential protection is the best technique in protection. Percentage differential relay for protection of three phase. Percentage restrained differential, percentage of what. Busbar differential protection radss 3phase 1mrk 505 008ben page 4 applicationapplication contd contd the ar has a fixed setting of about 30 ma, or 3% when based on a rated 1 a input current. The slope characteristic provides high sensitivity when low levels of. Twowinding current differential protection sensitive current differential protection with programmable single or dualslope percentage restraint, supervised by the second and fifthharmonic elements for secure differential protection on twowinding apparatus. A currentbased solution for transformer differential protection part i. These elements use operate and restraint quantities calculated from the two, three, or fourwinding input currents. Differential protection is not supposed to operate for a through fault. Matlabsimulink platform were used to analyze differential protection relay for a large power transformer.
Because of that, comparison of upstream and downstream currents in the same phases is not convenient for transformer differential protection. Iid52a 1 generators 21 5 iid52b 3 generators 22 6 iid53c 1 transformers 21 16 iid53d 3 transformers 22 17 the type lid relays comprise a group that is used for differential protection of alternating cur. Principles of differential relaying the restraint characteristic what needs to be realised is that the first one is properly termed the restraint characteristic rc whilst the latter is an operating characteristic. The focus of this paper is percentage restrained differential protection as applied to a power transformer. Type ca percentage differential relay for transformer. Power transformer differential protection using current. Partial differential relaying powell industries, inc. Protection functions bias differential protection 87 harmonic restraint protection over fluxing i. Sel587 current differential relay twoterminal apparatus. Thus this scheme provides protection to the greater percentage of the stator winding. As discussed in the post transformer differential protection, differential protection is supposed to operate for the internal faults or for the zone of protection it is intended for. Percentagerestraint differential protective relays have been. Dualslope percentage, harmonic restraint and blocking, plus dc blocking are included. It is a singlephase unit, and three relays are used for threephase transformer protection.
This basic percentage differential protection scheme forms the basis of the practically very commonly used percentage differential protection scheme for alternator stator windings. Transformer differential protection percentage restraint differential protective relays have been in service for many years 1. It is a static device, totally enclosed and usually oil immersed, and therefore the fault occurs on them are usually rare. True bus differential relaying compares all currents entering and leaving a switchgear bus. Review the application and ensure that it has been applied correctly. Transformer differential protection must deal with fictitious differential signals caused by magnetizing inrush conditions while striving for fast operation and sensitivity to turntoturn faults, for example.
What is merz price protection percentage differential. The type ca percentage differential relay for trans former protection is designed for the protection of power transformer. There are two general typesthose used for generator and reactor protection and those usedfor transformer protection. Pdf line differential protection modeling with composite. Percentage differential relays the ca16 relay is a singlephase differential relay used for protection of multicircuit buses up to a total of six circuits. Abstractpercentage restrained differential protection is one of the oldest forms of adaptive protection algorithms. It is, however, recognized that the percentage differential relay can maloperate due to various phenomena related to the nonlinearities in the transformer core. Basic percentage differential protection scheme for. Percentage differential protection slope transformer scribd. Harmonic restraint types std15c and std16c ge protection and control 205 great valley parkway malvern, pa 1935537. Introduction transformers are a critical and expensive component of the power system.
Percentage differential protection free download as word doc. The percentage differential relay is defined as the relay that operates on the phase difference of two or more similar electrical quantities. L to limit current through relay to percentage differential protection scheme forms the basis of the practically very commonly used percentage differential protection scheme for alternator stator windings. The relays used in power system protection are of different types.
Current balance differential protection voltage balanced differential protection 1. You will know how the characteristics of percentage restrained differential protection can be adjusted to take into account saturation of the current transformers. In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected 4 the first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as overcurrent, overvoltage, reverse power flow, overfrequency, and underfrequency. Each type of differential protection faces its own unique challenges.